Analyzer: Mindray BS-120 BS-200 BS-300 BS-380 BS-400 Chema Diagnostica - Guidelines for automatic analyzers - Mindray BS series IUS.432.0.2 Directions for use Edition 2013-01-15 page 5 of 41. The United States). PrintFriendly and PDF. Mindray Bs 200 User Manual Pdf CLICK HEREMindray Solution for Immunoassay Tests. High Throughput and BS-2000M series as well as 10 l-200 l, with.
DESCRIPTION
A bench top, discrete and random access clinical chemistry analyzer with 200 tests per hourIt’s tailored for small laboratories (used as a main instrument); medium and big laboratories (used as a back-up instrument)
FORUMSView All (28)
Ask a New QuestionMindray Bs 200 Service Manual Pdf
1Reply6 months ago | 6 months agoConnection with LIS error I try to connect with BS-200E via TCP/IP after I set up our LIS destinate IP/Port on the analyzer and connect successfully but I still didn't receive the result from our application (The send button is enable but I don't want to send manually) Please help me.Reply |
-m.krawczyk 7 months ago | 7 months agoDownloading sample from LIS to analyzer via tcp Hello.I am working on LIS and have a problem with sending samples to analyzer. Receiving result works well, but sending samples... well not at all. Communication seems good i received ACK^Q03 every sent sample, but they don't register in software.So I have some question:1. What about DSP - 29 filed where tests number are set. How it should look when I use 'Code on LIS' mapping? It should contains only number? Like ex. DSP|29||1^^^||| 2. Where can I find 'ItemID.ini' file which is mention in 'Host Interface Manual'? It doesn't appear in installation folder.3. Is there analyzer (BS-200) is required to register samples in software? Because manually you can, maybe there is restriction for downloading samples.4. There is any chance to use 'Code on LIS' mapping instead of numbers fixed? Ex:DSP|29||1^^^||| -> DSP|29||^AMY^^||| Reply |
1Reply8 months ago | 8 months agoProblem of assigning sample position using LIS in Mindray BS-200 I have developed an App that connects my LIS to analyzer Mindray BS-200 using hl7 protocol via TCP. Everything worked correctly, the results are received from the analyzer and the requests of test are sent successfully to analyzer. The only problem I have met is that, when i send a request of test to analyzer, the sample position is not assigned, it still be blank. Consequently, the process of analyzing can not be launched; since the position field is empty.I would appreciate any advise for solving this problem.Reply |
DOCUMENTS / MANUALSView All
Mindray Dp 50 User Manual
FEATURES
- 200 tests per hour, up to 330 tests per hour with ISE
- Up to 40 positions for samples and reagents respectively
- Automatic probe cleaning, liquid level detection, collision protection
- 8 wavelengths
- Refrigerated reagent compartment
- Bi-directional LIS interface
SPECIFICATIONS
Mindray Bs 200 Manual Pdf
Wavelength Range | 340 to 670 nm |